The details of this installation are listed below:
• The station is connected to a station return loop.
• The station return loop overlaps with Wire 1 and Wire 2.
• Wire 1 overlaps with Wire 3.
• Wire 3 overlaps with Wire 4.
• Wire 4 is a considerable distance from the charging station. To economize on the length
of wire to return from this field to the charging station an additional box has been installed
next to Wire 4 to house a signal channel board.
Configuration
The essential configuration parameters for this installation are given below.
For details on all the configuration parameters see the
1.
Press
2.
Select
3.
On the "Wire settings" screen, select the first entry in the list
4.
Rename this Wire to
5.
Select
6.
Check the value shown at the top of the screen. This should be positive. If it is not, select
Reverse phase
7.
Press
8.
Select
channel number to each and check the phase value.
9.
Press
Turfmow 1000 Technician's Manual
Figure 93: Multi-field installation for a complex garden
on the interface screen for a few seconds to obtain the technician's menu.
9
>
Infrastructure
Peripheral wires
.
LOOP
and assign the channel number for the small station loop.
Signal channel
and check the button ON.
to return to the "Wire Settings" screen.
and create four more wire (Wires 1-4). Assign the required
Create new wire
to return to the Infrastructure menu.
Version: Release 3.5
Technician's menu
.
Wire CH{X}
Last updated: 2018-12-20
Chapter 7 Installation
(page 114).
.