Chapter 12 Repair
When installing a replacement reed cable set, visually examine the position to ensure that the
relays align correctly. Run the service test to check whether spacers need to be inserted or
removed.
Figure 111: Positioning of magnets and the reed relays
Magnets
The magnets must be fixed to the lid as shown below. The parts required are
- YB-034-00000 Bonnet magnet
- YB-505-03012 Screw M3x12
Figure 112: Location of the magnets on the lid
The magnets must be magnets must be at the correct height so that when the lid is closed
or pressed down they connect with the correct relays. If necessary spacers must be placed
behind the magnets, if they are too low and the position of the relays must be adjusted with
spacers if the magnets are too high. This can be determined by running the test. Select
>
>
from the
Technician's menu
(page 114).