3.7  Setting the EtherCAT Node ID
Item
A
B
C
EtherCAT Node ID Address Example
Use the following example to understand how to set the EtherCAT node ID. An EtherCAT
node ID of 196 is used in this example.
1. Convert the node ID of 196 into hexadecimal format (0x0C4).
2. Set the x256 dip switch to OFF.
60
Figure 3-15. Robot Interface Panel EtherCAT ID Switches
Switch
2-Position Dip Switch
x256
16-Position Rotary Switch
x16
16-Position Rotary Switch
x1
iX4 650 H/HS and 800 H/HS Robot with EtherCAT
User's Manual (Cat. No. I656)
Description
Sets the 8th (most significant bit) of the 9-bit
EtherCAT node ID.
Moving the switch to the right turns ON the
8th bit for the node ID.
The default position is OFF (left).
Sets bits 7 to 4 of the EtherCAT node ID.
The default setting for this switch is 0.
Sets bits 3 to 0 of the EtherCAT node ID.
The default setting for this switch is 0.
22793-000 Rev. A