Sign In
Upload
Manuals
Brands
Omron Manuals
Barcode Reader
MicroHAWK ID-40
Omron MicroHAWK ID-40 Manuals
Manuals and User Guides for Omron MicroHAWK ID-40. We have
2
Omron MicroHAWK ID-40 manuals available for free PDF download: User Manual, Technical Note
Omron MicroHAWK ID-40 User Manual (354 pages)
Brand:
Omron
| Category:
Barcode Reader
| Size: 5 MB
Table of Contents
Table of Contents
3
About this Manual
8
Statements of Compliance
9
Warning and Caution Summary
10
Microhawk ID and Weblink Quick Start
12
Step 1 Check Hardware and Connect the System
12
Step 2 Mount and Position the Reader
13
Step 3 Install Weblink Drivers (ID-20 and ID-30)
14
Step 4 Connect to Weblink
15
Step 5 Explore the Start View
16
Step 6 Create a New Setup or Load an Existing Setup
17
Assisted Setup
17
Step 7 Explore the Setup View
18
Step 8 Configure Read Cycle Settings
19
Step 9 Configure Acquire Settings
21
Spot Focus
22
Step 10 Configure Symbology Settings
24
Step 11 Format Output and Configure Match String
25
Step 12 Configure Output 1, 2, and 3 Settings
26
Step 13 Run the Application
27
Microhawk ID and ESP Software Quick Start
28
Step 1 Check Hardware and Connect the System
28
Step 2 Mount and Position the Reader
29
Step 3 Install ESP
30
Minimum System Requirements
30
Step 4 Select Model
31
Step 5 Connect
32
Step 6 Locate the Symbol in the Field of View
33
Step 7 Calibrate
34
Calibrate by ESP
34
Step 8 Test Read Rate
35
Step 9 Configure the Reader in ESP
36
Step 10 Save Configuration in ESP
37
Saving Options
37
Microhawk ID Part Numbers
38
Using ESP
39
EZ Mode
40
App Mode
41
Menu Toolbar
42
Sizing Information
46
Connection Wizard
50
View
51
Navigating in ESP
52
Send/Receive Options
53
Advanced Options
54
Communications
55
Communications by ESP
56
Communications Serial Commands
57
Host Port Connections
58
Host Port Protocol
59
Point-To-Point (Standard)
59
Polling Mode
59
ACK/NAK Options
60
Polling Mode Options
61
Ethernet
62
IP Address Mode
64
Response Timeout
68
LRC (Longitudinal Redundancy Check) Status
69
Protocol Configuration Examples
70
Preamble
71
Preamble Characters
71
Postamble
72
Postamble Characters
72
USB Hid/Keyboard
73
Keyboard Language
73
Keyboard Languages
74
Ethernet/Ip Byte Swapping Enabled
78
Profinet
79
USB Mass Storage Driver
80
Entering ASCII Characters as Hex Values
81
Calibration
83
Calibration Serial Commands
84
Calibration Overview
84
Calibration Options
85
Quick Focus
87
Symbol Type
88
Straight Line
90
Calibration by ESP
92
After Calibration
93
Initiating Calibration
94
Additional Notes about Calibration
95
Read Cycle by ESP
98
Read Cycle Serial Commands
99
Read Cycle Setup
100
Multisymbol
101
Number of Symbols
101
Multisymbol Separator
101
Trigger Mode and Filter Duration
102
Continuous Read
102
Continuous Read 1 Output
103
Serial Data
105
External Trigger Polarity
107
Serial Trigger
108
Serial Trigger Character (Delimited)
108
Start Trigger Character (Non-Delimited)
109
Stop Trigger Character (Non-Delimited)
110
End of Read Cycle
111
End of Read Cycle Mode
111
Timeout or New Trigger
112
Last Frame or New Trigger
112
Read Cycle Timeout
112
Capture Mode
113
Continuous Capture
113
Number of Captures
114
Timed Capture
115
Triggered Capture
116
Capture Timing
118
Time between Captures
119
Image Processing Timeout
120
Image Storage
121
Image Storage Type
121
Image Storage Mode
121
Minimum Good Reads
123
Symbologies
125
Symbologies by ESP
126
Symbologies Serial Commands
127
Data Matrix
128
Aztec
130
QR Code
131
Micro QR Code
132
Code 39
133
Code 128/EAN 128
136
Bc412
139
Interleaved 2 of 5
140
Code 93
143
Codabar
144
Upc/Ean
147
EAN Status
147
Supplementals Status (UPC/EAN)
148
Separator Status (UPC/EAN)
148
Separator Character (UPC/EAN)
149
Pharmacode
151
Fixed Symbol Length Status (Pharmacode)
151
Minimum Number of Bars (Pharmacode)
151
Bar Width Status (Pharmacode)
152
Direction (Pharmacode)
152
Fixed Threshold Value (Pharmacode)
152
Postal Symbologies
153
Australia Post
155
GS1 Databar
158
Databar Expanded
158
Pdf417
160
Micropdf417
161
Composite
162
Separator Status (Composite)
162
Separator Character (Composite)
162
Dotcode
163
Rotation Mode
163
I/O Parameters by ESP
166
I/O Parameters Serial Commands
167
Symbol Data Output
168
When to Output Symbol Data
170
No-Read Message
172
Read Duration Output
173
Read Duration Output Mode
173
Read Duration Output Separator
173
Output Indicators
174
Green Flash Mode
174
Green Flash Duration
177
LED Configuration
178
Serial Verification
179
Serial Command Echo Status
179
Control/Hex Output
179
Setup Button
180
Global Status
180
Setup Button Modes
182
Target System
183
Bar Code Configuration
183
Configurable Output 1
184
Trend Analysis
185
Output State
186
Pulse Width
186
Output Mode
186
Trend Analysis Output 1
187
Trend Analysis Mode
188
Trigger Evaluation Period
189
Number to Output on
189
ISO/IEC 16022 Symbol Quality Output 1
190
Output on Symbol Contrast
190
Output on Print Growth
190
Output on Axial Non-Uniformity
191
Symbol Contrast Threshold
191
Print Growth Threshold
192
Axial Non-Uniformity Threshold
192
Diagnostic Output 1
193
Service Unit
193
Configurable Output 2
194
Trend Analysis Output 2
194
ISO/IEC 16022 Symbol Quality Output 2
194
Diagnostic Output 1
194
Configurable Output 3
195
Trend Analysis Output 3
195
ISO/IEC 16022 Symbol Quality Output 3
195
Diagnostic Output 3
195
Power-On/Reset Counts
196
Power-On Saves
196
Time Since Reset
197
Service Message
198
User-Assigned Name
199
Frame Information
200
Image Output
201
Communication Port
202
File Format
202
JPEG Quality
202
Database Identifier Output
204
Output Status
204
Quality Output
205
EZ Trax Output
206
Image Mode
206
Image Format
207
Image Push to Host
209
Image File Format
210
Image Quality
210
Image Scale
210
Image Push to Host Detailed Setup
211
Symbol Quality
215
Symbol Quality by ESP
216
Symbol Quality Serial Commands
217
Overview of Symbol Quality
218
Report Tab
219
Preferences Tab
221
Symbol Quality Separator/Data Matrix Output Mode
222
ISO/IEC 16022 Symbol Quality Output
224
Symbol Contrast
224
Print Growth
224
ISO/IEC 16022 Symbol Quality Output by ESP
226
Microscan Symbol Quality Output
227
Decode Time
228
Microscan Symbol Quality Output by ESP
230
Matchcode by ESP
232
Matchcode Serial Commands
233
Overview of Matchcode
234
Matchcode Type
235
Sequential Matching
236
Match Start Position
236
Match Length
236
Wild Card Character
237
Sequence on No-Read
238
Sequence on Mismatch
239
Sequence Step Interval
240
Match Replace
241
Mismatch Replace
242
New Master Pin
243
Camera and IP Setup by ESP
246
Camera and IP Setup Serial Commands
247
Video
248
Evaluation
249
Calibration
252
Window of Interest
253
Important Notes
256
Configuration Database
257
Dynamic Setup
258
Pixel Binning
259
Camera Settings
260
White Balance Settings
261
Color Filter
262
General Purpose
262
Focus Setup
263
Focal Distance
263
Distance Units
263
Focus Mode
263
Illumination Brightness
265
Light Source
265
Morphological Pre-Processing
266
Morphological Operation and Operator Size
267
Damaged Symbol
270
Linear Security Level
271
Set License
272
Configuration Database
273
Configuration Database Serial Commands
274
Number of Active Indexes
275
Configuration Database Status
276
Database Mode
282
Switch Mode
282
Region of Interest (ROI)
285
Save Current Settings to Configuration Database
287
Load Current Settings from Configuration Database
288
Request Selected Index Settings
289
Request All Configuration Database Settings
289
Terminal
292
Find
293
Send
294
Macros
295
Editing a Macro
295
Terminal Menus
296
Terminal Dropdown Menu
296
Operational Commands
298
Read Rate
300
Counters
302
Counters by Serial Command
303
Device Control
304
Differences from Default
305
Master Database
306
Master Symbol Database Size
307
Enter Master Symbol Data
308
Request All Master Symbol Data
309
Read Next Symbol as Master Symbol
310
Request New Master Status
310
Delete Master Symbol Data
311
Firmware
312
Firmware Update
312
Firmware Verification
313
Default/Reset/Save
315
Saved for Power-On
315
Customer Default Parameters
316
Microscan Default Parameters
316
Reader Status Requests
317
Other Operational Serial Commands
319
Bar Code Configuration Mode
322
Output Format
323
Output Format Serial Commands
324
Output Format Status
325
Output Format Status Disabled
325
Output Format Status Enabled
325
Format Assign
326
Symbol Number
326
Format Extract
327
Start Location
327
Format Extract by ESP
328
Format Insert
329
Hex String
329
Format Insert by ESP
330
Output Filter Configuration
331
Rules for Output Filter Configuration
331
Database Index
334
Number of Filters
336
Appendices
337
Appendix A General Specifications
338
Appendix B Electrical Specifications
344
Grounding and Isolation
345
Appendix C Serial Commands
346
Serial Command Status Request
347
Appendix D Communications Protocol
348
Appendix E ASCII Table
349
Appendix F Glossary of Terms
350
Advertisement
Omron MicroHAWK ID-40 Technical Note (38 pages)
360 Barcode Reading to Omron NJ/NX Controller
Brand:
Omron
| Category:
Barcode Reader
| Size: 3 MB
Advertisement
Related Products
Omron MicroHAWK V320-F
Omron MicroHAWK V330-F
Omron MicroHAWK V420-F
Omron MicroHAWK V430-F
Omron IDSC-C1DT-A
Omron IDSC-C1DR-A
Omron MicroHAWK ID/MV-20
Omron INTELLISENSE BP755
Omron Intelli Sense ELITE 7300W
Omron i4-450L
Omron Categories
Blood Pressure Monitor
Controller
Accessories
Switch
Inverter
More Omron Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL