L3560, L4060, L4760, L5060, L5460, L6060, WSM
Rectifier
1. Check the continuity across each diode of rectifier with an
analog ohmmeter. Conduct the test in the (R × 1) setting.
2. The rectifier is normal if the diode in the rectifier conducts in one
direction and does not conduct in the reverse direction.
IMPORTANT
• Do not use a 500 V megohmmeter for measuring because it
will destroy the rectifier.
NOTE
• Do not use an auto digital multimeter. Because it's very
hard to check the continuity of rectifier by using it.
IC Regulator
1. Check the continuity across the B terminal and the F terminal of
IC regulator with an analog ohmmeter. Conduct the test in the
(R × 1) setting.
2. The IC regulator is normal if the IC regulator conducts in one
direction and does not conduct in the reverse direction.
IMPORTANT
• Do not use a 500 V megohmmeter for measuring because it
will destroy the IC regulator.
NOTE
• Do not use an auto digital multimeter. Because it is very
hard to check the continuity of IC regulator by using it.
9-S97
ELECTRICAL SYSTEM
9Y1210824ELS0147US0
9Y1210824ELS0148US0
KiSC issued 03, 2016 A