Kubota WSM L3560 Workshop Manual page 130

Table of Contents

Advertisement

L3560, L4060, L4760, L5060, L5460, L6060, WSM
Injector Operation
 No Injection
While the solenoid (2) is not electrified, the two way
electromagnetic valve (3) is pushed down by the valve
spring (1) and the discharge orifice (11) path is closed by
the valve ball (4). Here, fuel pressure is applied in the
control chamber (5) and to the bottom of the needle
valve (8) but based on the difference in projected net
area and the force of the nozzle spring (7), the needle
valve is pushed into the nozzle body (9) so fuel injection
is not performed.
(1) Valve Spring
(2) Solenoid
(3) Two Way Electromagnetic
Valve
(4) Valve Ball
(5) Control Chamber
(6) Valve Piston
 Injection Start
When the solenoid (1) is electrified by the drive
circuit (6) the two way electromagnetic valve (2) is lifted
by an electromagnetic force and the valve ball (3) is lifted
by fuel pressure opening the discharge orifice (7). Here,
fuel inside the control chamber (4) passes through the
discharge orifice and flows to the fuel tank. As a result,
the needle valve (5) is pushed up based on fuel pressure
and fuel injection starts.
NOTE
• Longer electrification time of the solenoid leads
to increased amount of fuel injected.
(1) Solenoid
(2) Two Way Electromagnetic
Valve
(3) Valve Ball
(4) Control Chamber
 Injection Complete
When electrification of the solenoid (2) by the drive
circuit (9) stops, the two way electromagnetic valve (3) is
pushed closed by the force of the valve spring (1) and
the discharge orifice (9) is closed by the valve ball (4). As
a result, fuel pressure in the control chamber (5) rises
and the needle valve (7) is pushed by the valve piston
(6).
(1) Valve Spring
(2) Solenoid
(3) Two Way Electromagnetic
Valve
(4) Valve Ball
(5) Control Chamber
1-M15
ENGINE
(7) Nozzle Spring
(8) Needle Valve
(9) Nozzle Body
(10) Drive Circuit
(11) Discharge Orifice
(12) Suction Orifice
9Y1210824ENM0021US0
(5) Needle Valve
(6) Drive Circuit
(7) Discharge Orifice
9Y1210824ENM0022US0
(6) Valve Piston
(7) Needle Valve
(8) Drive Circuit
(9) Discharge Orifice
9Y1210824ENM0023US0
KiSC issued 03, 2016 A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wsm l4060Wsm l4760Wsm l5060Wsm l5460Wsm l6060

Table of Contents