PM warning level 0 to 5 as shown below is set according to the amount of accumulated PM to prompt the operator
to perform the required procedure in each level.
• Level 0: Normal operation. Regeneration is not required.
• Level 1: Auto Regeneration is possible in the Auto Regeneration Mode.
• Level 2: Auto Regeneration is possible in the Auto Regeneration Mode. Parked Regeneration is possible in both
of the Auto Regeneration Mode and Inhibit Mode.
• Level 3: Auto Regeneration is not possible in above level 3. Parked Regeneration is required as soon as possible.
• Level 4: Only by using diagmaster, Parked Regeneration is possible. Parked Regeneration is required as soon
as possible.
• Level 5: Cleaning or replacement is required. Regeneration is not possible.
Auto Regeneration Mode
Engine
Warning
Buzzer
output
level
limitation
No
0
No
limitation
No
1
No
limitation
Level 2-1: Every 5
second
No
Level 2-2: Every 3
limitation
second
Every
3
50 %
second
Every
4
50 %
second
Every
5
50 %
seconds
 : Blink,  : ON
1-M27
Remark
Normal operation, Regeneration is not required.
Condition for Auto Regeneration is not satisfied and engine
speed is low.
DPF temperature for Auto Regeneration is not satisfied.
Engine speed is OK.
Under the Auto Regeneration.
Condition for Auto Regeneration is not satisfied and engine
speed is low.
DPF temperature for Auto Regeneration is not satisfied.
Engine speed is OK.
Under the Parked Regeneration.
Condition for Parked Regeneration is not satisfied.
Condition for Parked Regeneration is satisfied. When
pressing the parked regeneration switch, Parked
Regeneration will start.
Under the preparation for Parked Regeneration.
Under the Parked Regeneration.
Without diagmaster.
When using diagmaster and condition for Parked
Regeneration is not satisfied.
This indication switch to the following if cancel the DPF
INHIBIT switch in the state of condition for Parked
Regeneration is satisfied.
When using diagmaster and condition for Parked
Regeneration is satisfied. When pressing the parked
regeneration switch, Parked Regeneration will start.
Under the preparation for Parked Regeneration when using
diagmaster.
Under the Parked Regeneration when using diagmaster.
Even when using diagmaster, it is not possible to carry out
Parked Regeneration.