L3560, L4060, L4760, L5060, L5460, L6060, WSM
Error Message Does not Indicate on LCD (HST)
Symptom
System Will Not
Operate in Either
Direction
Vibration and Noise
Probable Cause
Oil level is low
Charge pressure is too low
Check and high pressure relief valve does not
move smoothly
Component parts damaged
Electronic control parts damaged
Oil level is too low
Charge pressure is too low
Check and high pressure relief valve does not
move smoothly
Component parts damaged
Check oil level or fill
oil to proper level
Solution order
1. Replace oil filter
cartridge
2. Check charge
pressure
3. Inspect or flush
charge relief valve
Inspect or replace
check and high
pressure relief valve
Replace hydrostatic
transmission
assembly
Inspect or replace
electronic control
parts
Check oil level or fill
oil to proper level
Solution order
1. Replace oil filter
cartridge
2. Check charge
pressure
3. Inspect or flush
charge relief valve
Inspect or replace
check and high
pressure relief valve
Replace hydrostatic
transmission
assembly
3-S10