Monitoring Parameters
Register
Name
No.
Run Status
IW00
Parameter Number
When Range Over is
IW01
Generated
Warning
IL02
Alarm
IL04
Position Management
IW0C
Status
Machine Coordinate
System Feedback
IL16
Position (APOS)
Machine Coordinate
System Latch Position
IL18
(LPOS)
Target Position
IL1C
Difference Monitor
General-purpose DI
IW58
Monitor
General-purpose AI
IW59
Monitor 1
General-purpose AI
IW5A
Monitor 2
4.4.1 Motion Parameters That Can be Used in General-purpose I/O Mode
Description
Bit 0: Motion Controller Operation Ready
Setting parameters: 0 and onward
Fixed parameters: 1000 and onward
Bit B: Analog Adjust Not Ready Warning
Bit 14: PG Disconnection Error
Bit 2: ON at Latch Completed (LCOMP)
Used as the counter current position.
31
31
Range: −2
−1
to 2
Unit: 1 = 1 reference unit (pulse only)
Used as the counter latch position.
31
31
Range: −2
−1
to 2
Unit: 1 = 1 reference unit (pulse only)
Used as the number of incremental pulses of feedback.
31
31
Range: −2
−1
to 2
Unit: 1 = 1 reference unit (pulse only)
Bit 0: General-purpose DI_0
Bit 1: General-purpose DI_1
Bit 2: General-purpose DI_2
Bit 3: General-purpose DI_3
Bit 4: General-purpose DI_4
Bit 5: General-purpose DI_5
Bit 6: Reserved for system use
Bit 7: PG Wire Breaking Down Status (ON: Connected/1: Disconnected)
Range: −32768 to 32767
Unit: 1 = 0.001 V
Range: −32768 to 32767
Unit: 1 = 0.001 V
4.4 General-purpose I/O Mode
4
4-7