7.2 Motion Command Details
7.2.3 Zero Point Return (ZRET)
<Starting on the Positive Stroke Limit (P-OT)>
The stopping method when the OT signal is detected depends on the setting of SERVOPACK parameters.
Parameters to be Set
Parameter
OW03
Bits 0 to 3
OL10
OW18
OW3C
OL3E
OL42
7-46
N-OT (DI_4)
Name
Speed Unit Selection
Speed Reference
Setting
Override
Zero Point Return
Method
Approach Speed
Zero Point Return Travel
Distance
Zero Point
Select the setting unit for OL10 (Speed Reference Setting) and
OL3E (Approach Speed).
0: Reference unit/s
n
1: 10
reference units/min
2: Percentage of rated speed (1 = 0.01%)
3: Percentage of rated speed (1 = 0.0001%)
Set the positioning speed to use after detecting the P-OT signal. The sign is
ignored.
The travel direction will depend on the sign of the Zero Point Return Travel
Distance.
Setting to 0 or a negative value will result in an error.
This parameter allows the travel speed to be changed without changing the
Speed Reference (OL10). The setting can be changed during operation
moving.
Setting range: 0 to 32767 (0 to 327.67%)
Setting unit: 1 = 0.01%
13: P-OT Only Method
Set the speed to be used at zero point return start. Only a positive value can
be set. 0 or a negative value will result in an error.
Set the travel distance from the point where P-OT signal is detected.
The travel direction will depend on the sign. Always set to a negative value
when using P-OT Only Method.
Start
Zero Point
Return Travel
Distance
(OL
42)
Speed Reference
Setting
(OL
10)
P-OT (DI_3)
Setting