YASKAWA MP2000 Series User Manual page 287

Machine controller, motion module
Hide thumbs Also See for MP2000 Series:
Table of Contents

Advertisement

( 3 ) SERVOPACK Parameters for Absolute Position Detection
SERVOPACK
Parameter
Model
Pn000.0
Σ
-III Series
(SGDS),
Σ
-V Series
Pn205
(SGDV),
Pn212
Σ
-7 Series
(SGD7S)
Pn002.2
Pn000.0
Σ-II
Series
Pn205
(SGDM, SGDH)
Pn201
Pn002.2
Cn-0001,
Bit E
Σ-I
Series
(SGDA, SGDB)
Cn-0002,
Bit 0
10.4.2 Parameters Setting for Simple Absolute Infinite Length Position Control
Name
0: Sets counterclockwise (CCW)
rotation as forward direction.
Direction Selection
1: Sets clockwise (CW) rotation as
forward direction (reverse rotation
mode).
Multiturn Limit Setting
0 to 65535
PG Dividing Pulse
16 to 1073741824
0: Uses absolute encoder as an abso-
lute encoder.
Absolute Encoder Usage
1: Uses absolute encoder as an incre-
mental encoder.
0: Sets counterclockwise (CCW)
rotation as forward direction.
Direction Selection
1: Sets clockwise (CW) rotation as
forward direction (reverse rotation
mode).
Multiturn Limit Setting
0 to 65535
PG Divider
16 to 16384
0: Uses absolute encoder as an abso-
lute encoder.
Absolute Encoder Usage
1: Uses absolute encoder as an incre-
mental encoder.
0: Incremental encoder
Encoder Selection
1: Absolute encoder
0: Sets counterclockwise (CCW)
rotation as forward rotation.
Rotation Direction Selec-
1: Sets clockwise (CW) rotation as
tion
forward rotation (reverse rotation
mode).
10.4 Absolute Position Detection for Infinite Length Axes
Setting Range
Units
Rev
P/Rev
Rev
P/Rev
Reference
Caution
10.4.3 ( 3 )
10.4.3 ( 3 )
10.4.3 ( 1 )
10.4.3 ( 3 )
10.4.3 ( 2 )
10.4.3 ( 1 )
10.4.3 ( 1 )
10-17
10