YASKAWA MP2000 Series User Manual page 180

Machine controller, motion module
Hide thumbs Also See for MP2000 Series:
Table of Contents

Advertisement

Starting the Zero Point Return in Region E
1.
The axis travels in the reverse direction at the Approach Speed (setting parameter OL3E).
2.
When the rising edge of the DEC1 signal is detected, the axis decelerates to a stop.
3.
After decelerating to a stop, the axis travels in the forward direction at the Creep Rate (setting parame-
ter OL40).
4.
After the falling edge of the DEC1 signal is detected, the position is latched when the rising edge of the
first phase-C pulse is detected.
5.
The axis moves from the latched position by the distance set in the Zero Point Return Travel Distance
(setting parameter OL42) and stops. The machine coordinate system is established with this final
position as the zero point.
N-OT
(DI_4)
DEC1
(DI_5 or OW
05, bit 8)
Zero Point Return
Reverse Run Side Limit
Signal (OW
05, bit 9)
Zero Point Return
Forward Run Side Limit
Signal
Phase-C signal
(OW
05, bit 10)
 If an OT signal is detected during the zero point return operation, an OT alarm will occur.
Region A
Region B
Phase-C signal
latch at this point
Region C
Region D
Creep Rate
(OL
40)
Zero Point Return Travel Distance
End
Approach Speed (OL
3E)
7.2 Motion Command Details
7.2.3 Zero Point Return (ZRET)
Region E
P-OT
(DI_3)
Start
7
7-41