8.1 Switchable Motion Commands
8.1.7 Switching from FEED
Switched From
FEED
8-20
Switched To
(2) When Not Using the Accel/Decel Filter for VELO Command
VELO
(cont'd)
Motion command
Motion command
response
FEED will immediately switch to TRQ, and the control mode will be changed from posi-
tion control mode to torque/thrust control mode.
The moving amount stored in the accel/decel filter will be reset to 0.
TRQ
Motion command
Motion command
response
 After FEED has switched to TRQ, the TRQ command will be executed without
the accel/decel filter. This is because TRQ is a motion command for which the
accel/decel filter is disabled.
FEED will immediately switch to PHASE, and the control mode will be changed from
position control mode to phase control mode.
The moving amount stored in the accel/decel filter will be reset to 0.
PHASE
Motion command
Motion command
response
 After FEED has switched to PHASE, the PHASE command will be executed
without the accel/decel filter. This is because PHASE is a motion command
for which the accel/decel filter is disabled.
Operation
The speed will smoothly change.
The speed at the time the motion command is switched will
increase/decrease until it reaches the VELO target speed.
The accel/decel filter for FEED command will be cancelled.
FEED
VELO
FEED
FEED
Position control mode
Speed control mode
The reference value of the TRQ
command will be output as it is regardless
of the speed at the time the motion
command is switched to TRQ.
FEED
TRQ
FEED
FEED
Position control mode
Torque control mode
The reference value of the PHASE
command will be output as it is regardless
of the speed at the time the motion
command is switched to PHASE.
FEED
PHASE
FEED
PHASE
FEED
PHASE
Position control mode
Phase control mode
VELO
VELO
TRQ
TRQ