5.4 MP2000 Series Machine Controller Parameter Details
5.4.3 Motion Monitoring Parameter Details
IW0C
Position Management Status (cont'd)
Bit 5
Bit 6
Bit 7
Description
Bit 8
Bit 9
Bit A
( 10 ) Position Information 1
IL0E
Target Position in Machine Coordinate System (TPOS)
Stores the target position in the machine coordinate system managed by the Motion Module.
This is the target position per scan for INTERPOLATE or LATCH commands.
Description
IL10
Calculated Position in Machine Coordinate System (CPOS)
Stores the calculated position in the machine coordinate system managed by the Motion Module.
The position data stored in this parameter is the target position for each scan.
Description
5-48
Zero Point Return (Setting) Completed (ZRNC)
0: Zero point return (setting) not completed.
1: Zero point return (setting) completed.
This bit turns ON when a zero point return (setting) has been completed.
This bit turns OFF when a new zero point return (setting) operation is started.
During Machine Lock (MLKL)
0: Machine lock mode released.
1: Machine lock mode.
This bit turns ON when the Machine Lock bit is set to 1 in the Run Command Setting (setting parameter
OW00, bit 1) and the axis has actually entered machine lock mode.
Absolute Position Read-out Completed
0: OFF
1: ON (Reading completed)
This bit turns ON when reading the absolute data by setting the setting parameter Absolute Position Reading
Demand (OW00, bit 5) to 1 (reading ON) has been completed.
This bit stays OFF when the setting parameter Absolute Position Reading Demand (OW00, bit 5) is set to 0
(reading OFF).
ABS Rotary Pos. LOAD Complete (ABSLDE)
0: LOAD not completed.
1: LOAD completed.
This bit turns ON when the Request ABS Rotary Pos. Load bit is set to 1 in the Run Command Setting (setting
parameter OW00, bit 7) and loading of the information has been completed.
 Invalid for linear type.
POSMAX Turn Preset Complete (TPRSE)
0: Preset not completed.
1: Preset completed.
This bit turns ON when the POSMAX Turn Number Presetting Demand bit in the Run Command Setting (set-
ting parameter OW00, bit 6) is set to 1 and the POSMAX Number of Turns has been preset with the Num-
ber of POSMAX Turns Presetting Data (setting parameter OL4C).
 Invalid for linear type.
ABS Encoder Rotating Direction
0: Forward rotation
1: Reverse rotation
• This parameter will be set to 0 when the power supply is turned ON.
• The data is refreshed even when the machine lock mode is enabled.
• This parameter will not be reset even when an infinite length axis type is selected.
• This parameter will be set to 0 when the power supply is turned ON.
• The data is updated even when the machine lock mode is enabled.
• When an infinite length axis type is selected, a range of 0 to (Maximum Value of Rotary Counter (POSMAX) − 1) is
stored.
Range
Range
31
31
Reference unit
−2
to 2
−1
Range
31
31
Reference unit
−2
to 2
−1
Unit
Unit
Unit