YASKAWA MP2000 Series User Manual page 265

Machine controller, motion module
Hide thumbs Also See for MP2000 Series:
Table of Contents

Advertisement

Switched From
Switched To
FEED
(cont'd)
PHASE
STEP
(2) When Not Using the Accel/Decel Filter for FEED Command
The speed will smoothly change.
The speed at the time the motion command is
switched will increase/decrease until it reaches
the FEED target speed.
The accel/decel filter will be cancelled.
Motion command
Motion command
response
Phase control mode
PHASE will immediately switch to STEP, and the control mode will be changed from
phase control mode to position control mode.
 STEP switched from PHASE starts its operation with the empty accel/decel fil-
ter. Therefore, when the accel/decel filter is set for STEP command, the
speed will not smoothly change, and the distribution will be started from the
state Speed = 0 (see (1).) To change the speed smoothly, do not set the filter
for STEP command (see (2))
(1) When Using the Accel/Decel Filter for STEP Command
Distribution will start from the
state SPEED = 0 since the accel/
decel filter is empty.
Motion command
Motion command
response
Phase control mode
(2) When Not Using the Accel/Decel Filter for STEP Command
The speed will smoothly change.
The speed at the time the motion command is
switched will increase/decrease until it reaches
the STEP target speed.
The accel/decel filter will be cancelled.
Motion command
Motion command
response
Phase control mode
8.1 Switchable Motion Commands
8.1.12 Switching from PHASE
Operation
PHASE
FEED
PHASE
FEED
PHASE
FEED
Position control mode
PHASE
STEP
PHASE
STEP
PHASE
STEP
Position control mode
PHASE
STEP
PHASE
STEP
PHASE
STEP
Position control mode