YASKAWA MP2000 Series User Manual page 261

Machine controller, motion module
Hide thumbs Also See for MP2000 Series:
Table of Contents

Advertisement

Switched From
Switched To
TRQ
PHASE
TRQ will immediately switch to PHASE, and the control mode will be changed from
torque/thrust control mode to phase control mode. The moving amount stored in the accel/
decel filter will be reset to 0.
The reference value of the PHASE command
will be output as it is regardless of the speed
at the time the motion command is switched
to PHASE.
Motion command
Motion command
response
Torque
control mode
 After TRQ has switched to PHASE, the PHASE command will be executed
without the accel/decel filter. This is because PHASE is a motion command
for which the accel/decel filter is disabled.
8.1 Switchable Motion Commands
8.1.11 Switching from TRQ
Operation
TRQ
PHASE
TRQ
PHASE
TRQ
PHASE
Phase control mode
8
8-35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents