Setting of acceleration/deceleration time and acceleration/ deceleration pattern

4.8
Setting of acceleration/deceleration time and acceleration/
deceleration pattern
Purpose
Motor acceleration/deceleration
time setting
Starting frequency
Set acceleration/deceleration
pattern suitable for application
Automatically set optimum
acceleration/deceleration time.
4.8.1
Setting of the acceleration and deceleration time
(Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45, Pr. 147)
Used to set motor acceleration/deceleration time.
Set a larger value for a slower speed increase/decrease or a smaller value for a faster speed increase/decrease.
For the acceleration time at automatic restart after instantaneous power failure, refer to Pr. 611 Acceleration time at a
restart (page 161).
Parameter
Name
Number
7
Acceleration time
8
Deceleration time
Acceleration/
deceleration
20 ∗1
reference
frequency
Acceleration/
21 ∗1
deceleration time
increments
Second
44 ∗1
acceleration/
deceleration time
Second
45 ∗1
deceleration time
108
Parameter that should be Set
Acceleration/deceleration
times
Starting frequency and
start-time hold
Acceleration/deceleration
pattern
Automatic acceleration/
deceleration
Initial Value
FR-E720-175(SC) or less
FR-E740-095(SC) or less
FR-E720S-110 or less
FR-E710W-050 or less
FR-E720-240(SC) and 330(SC)
FR-E740-120(SC) and 170(SC)
FR-E720-470(SC) and 600(SC)
FR-E740-230(SC) and 300(SC)
FR-E720-175(SC) or less
FR-E740-095(SC) or less
FR-E720S-110 or less
FR-E710W-050 or less
FR-E720-240(SC) and 330(SC)
FR-E740-120(SC) and 170(SC)
FR-E720-470(SC) and 600(SC)
FR-E740-230(SC) and 300(SC)
60Hz
0
FR-E720-175(SC) or less
FR-E740-095(SC) or less
FR-E720S-110 or less
FR-E710W-050 or less
FR-E720-240(SC) and 330(SC)
FR-E740-120(SC) and 170(SC)
FR-E720-470(SC) and 600(SC)
FR-E740-230(SC) and 300(SC)
9999
Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44,
Pr. 45, Pr. 147
Pr. 13, Pr. 571
Pr. 29
Pr. 61 to Pr. 63, Pr. 292
Setting
Range
5s
0 to 3600/
Motor acceleration time.
360s ∗2
10s
15s
5s
0 to 3600/
Motor deceleration time.
360s ∗2
10s
15s
Frequency that will be the basis of
acceleration/deceleration time.
1 to 400Hz
As acceleration/deceleration time, set the
frequency change time from stop to Pr. 20.
Increments: 0.1s
0
Range: 0 to
3600s
Increments: 0.01s
1
Range: 0 to 360s
5s
0 to 3600/
Acceleration/deceleration time when the RT
360s ∗2
signal is ON.
10s
15s
0 to 3600/
Deceleration time when the RT signal is
360s ∗2
ON.
9999
Acceleration time = deceleration time
Refer to Page
108
111
112
113
Description
Increments and setting
range of acceleration/
deceleration time
setting can be
changed.