Continue with your configuration settings. After you have completed all of your
configuration settings, connect to your TX3 system and send the job (see section
3.13, Sending Your Configuration, on page 98).
3.4
Access Point Timer Options
You can set timers for criteria related to your access point, such as how long to
unlock the access point and how long to wait for the anti-passback restriction to
expire. The timers for each access point are accessed by selecting the access
point and then selecting the Timers tab. The following timers are associated
with the Aperio Door Controller System operation:
•
•
•
•
•
•
•
•
Each of these timers are explained in more detail in sections 3.4.1 to 3.4.8.
Section 3.4.9 explains how to set these timers for an access point.
3.4.1
Unlock Time
The door unlock timer starts when the door unlocks. When the timer expires the
door locks. The unlock timer is programmable from 0 to 300 seconds. The
default is 10 seconds.
3.4.2
Extended Unlock Time
The extended unlock timer is used for cards with the extended unlock feature
enabled. The timer starts when the door unlocks. When the extended unlock
timer expires the door locks. The extended unlock timer is programmable from
10 to 300 seconds. The default is 15 seconds.
3.4.3
Door Held Open Warning
The door held open warning timer starts when a door is still open after the unlock
or extended unlock timer expires. If the door is still open after the door held open
timer expires, a 'door held open' warning is issued to the PC and the common
trouble status becomes active. If the door closes during this interval, the timer
resets and no warning report is sent to the PC.
TX3 Aperio Door Controller System Installation and Operation Manual
76
LT-1160
Copyright 2019
Unlock Time
Extended Unlock Time
Door Held Open Warning
Door Held Open Alarm
Anti-passback
High Security Swipe Timer
Lock/Unlock Swipe Timer
Pin Timeout