Bit field:
Bit
Signal name
00
Controlled operation
01
Set ramp-function generator
02
Stop RsLh adaptation
03
Feedback
04
Encoder operation
05
Holding angle
06
Acceleration criteria
07
Set angular integrator PEM
08
Stop Kt adaptation PEM
09
PolID active PEM SLVC
10
I injection PEM
11
Speed controller output cannot be set to
zero
12
Rs adapt waits
13
Motor operation
14
Stator frequency sign
15
Torque sign
p1752[0...n]
Motor model changeover speed operation with encoder / MotMod n_chgov enc
SERVO
Can be changed: U, T
Data type: Floating Point
P-Group: Closed-loop control
Not for motor type: REL
Min
0.0 [RPM]
Description:
Sets the speed to change over the motor model for operation with encoder.
Dependency:
Refer to: p1756
Note:
Induction motor (ASM):
The motor model is influenced for speeds/velocities greater than p1752.
Synchronous motor (SRM):
A monitoring (F07412) is activated for speeds/velocities greater than p1752.
The motor model is additionally influenced when kT adaptation is activated (p1780.3 = 1).
p1752[0...n]
Motor model with encoder changeover velocity / MotMod v_chgov enc
SERVO (Lin)
Can be changed: U, T
Data type: Floating Point
P-Group: Closed-loop control
Not for motor type: REL
Min
0.0 [m/min]
Description:
Sets the velocity to change over the motor model for operation with encoder.
Dependency:
Refer to: p1756
Note:
Induction motor (ASM):
The motor model is influenced for speeds/velocities greater than p1752.
Synchronous motor (SRM):
A monitoring (F07412) is activated for speeds/velocities greater than p1752.
The motor model is additionally influenced when kT adaptation is activated (p1780.3 = 1).
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
1 signal
Active
Active
Yes
Active
Active
Yes
Active
No
No
No
No
Yes
Yes
Yes
Positive
Motor mode
Calculated: CALC_MOD_REG
Dynamic index: DDS, p0180
Units group: 3_1
Max
210000.0 [RPM]
Calculated: CALC_MOD_REG
Dynamic index: DDS, p0180
Units group: 4_1
Max
1000.0 [m/min]
Parameters
List of parameters
0 signal
FP
Inactive
-
Inactive
-
No
-
Inactive
-
Inactive
-
No
-
Inactive
-
Yes
-
Yes
-
Yes
-
Yes
-
No
-
No
-
No
-
Negative
-
Regenerative mode
-
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
210000.0 [RPM]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
1000.0 [m/min]
1-473