Power Led Error Codes - Matrox Iris GT MIL Installation And Technical Reference

Hide thumbs Also See for Iris GT MIL:
Table of Contents

Advertisement

156 Appendix G: Reading the LEDs
• Status LED. This LED shows the general activity of your Matrox Iris GT.
LED
Description
Off
There is no power.
Red
Matrox Iris GT is booting.
Orange
The Matrox Iris GT acquisition section is initializing or a MIL program is either waiting for a
trigger or using image files from disk.
Green
The Matrox Iris GT acquisition section is grabbing an image.

Power LED error codes

Whenever the User LED is blinking red while the Power LED is also red, an error
has occurred. These are errors declared by the bootloader at boot time. A text
version of the error message can be seen among the messages sent to the COM
port by the Matrox Iris GT. Note that this assumes the POST string print to
memory option is enabled on the Boot settings page, which can be accessed from
the Administration utility page of the Matrox Iris portal website.
The following only applies when the Power LED stays red while the User LED
blinks red.
User LED blink sequence
6-1-1-1-1
6-1-1-1-2
6-1-1-1-3
6-1-1-1-4
6-1-1-2-1
6-1-1-2-2
6-1-1-2-3
6-1-1-2-4
6-1-1-3-1
6-1-1-3-2
6-1-1-3-3
6-1-3-1-1
6-1-3-1-2
6-1-3-1-3
6-1-3-1-4
Error
Invalid error or unknown error.
Boot ROM checksum error.
CMOS error.
CMOS data error.
Maximum boot failure count reached.
Memory initialization error.
FPGA Load firmware error.
ROM interface block error.
CPU microcode update error.
Memory bus data line error.
Memory bus address line error.
RTC error.
100/1 GBase T Ethernet controller error.
Solid state device size error.
RAM row size error.