Connecting external devices to input signals

You can connect a wide variety of external devices to the input signals of your
Matrox Iris GT, such as external triggering devices.
Your Matrox Iris GT auxiliary input and trigger signals can have a 5 V, 12 V, or
24 V power source. For information regarding the electric specifications regarding
the ON and OFF voltage levels, see the Electrical specifications subsection of the
Matrox Iris GT specifications section, in Appendix B: Technical Reference.
An external resistor must be used when dealing with non-TTL signals:
Voltage
5 V
12 V
24 V
Connecting external devices to input signals
External resistor required
0 KΩ and 0 W
1 ΚΩ and ¼ W
3 KΩ and ¼ W