Connecting To A Ttl Device - Matrox Iris GT MIL Installation And Technical Reference

Hide thumbs Also See for Iris GT MIL:
Table of Contents

Advertisement

Connecting to a TTL device

To connect your Matrox Iris GT to a TTL device, you must first connect an
external pull-up resistor between them. The external pull-up resistor is needed
because TTL devices expect to be connected to a device that can provide power
(a sourcing device) and your Matrox Iris GT is a sinking device.
Connect an auxiliary output signal of your Matrox Iris GT and the device input
to an external pull-up resistor. In addition, connect the ground of the TTL device
and the ground of your Matrox Iris GT to a common ground.
The external pull-up resistor assures that when the output is disabled (off ), the
external resistor will pull-up the device's input to a positive voltage (+V).
Therefore, the device input is "on" when your Matrox Iris GT output is "off",
and vice-versa.
Matrox Iris GT digital I/O
and power connector
AUX(USER)_OPENC_OUT0
1
Note that the output can
sink up to 100 mA.
Connecting external devices to auxiliary output signals
Power
+5V
source
External
pull-up
resistor
1
GND
113
In 0
GND
TTL device

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents