Switch Boxes; Output-To-Trigger Bypass Switch Box; Output Pull-Up Resistor Switch Box - Matrox Iris GT MIL Installation And Technical Reference

Hide thumbs Also See for Iris GT MIL:
Table of Contents

Advertisement

150 Appendix F: The breakout board

Switch boxes

The switch boxes redirect the signals of your Matrox Iris GT. There are three
switch boxes, labeled SW6 through SW8, on the breakout board. Each switch box
has 4 switches.

Output-to-trigger bypass switch box

The output-to-trigger bypass switch box (SW6) allows you to route a Matrox
Iris GT auxiliary output signal to the Matrox Iris GT trigger signal, and allows
the trigger signal to be grounded when not from a third-party device.
Switch
Description (ON)
1
Routes the Matrox Iris GT AUX(STB)_OPENC_OUT4 signal to the TRIG_OPTO_IN0+ signal.
Note that if this switch is ON, switch 1 of the output-to-input bypass switch box (SW8[1])
cannot be on.
2
Grounds the Matrox Iris GT TRIG_OPTO_IN0- signal. Note that this is necessary when using
the trigger push button (Trig+), or when switch 1 of this switch box (SW6[1]) is on; otherwise,
by default, the negative opto-isolated trigger signal is floating (that is, it is not connected to
ground).
3
Reserved.
4
Diagnostic switch. Set this switch to OFF unless otherwise directed by technical support. If this
switch is ON, your Matrox Iris GT will not finish booting until it receives a CRLF through the
serial port.

Output pull-up resistor switch box

The output pull-up resistor switch box (SW7) is used when routing a Matrox
Iris GT auxiliary output signal to a Matrox Iris GT auxiliary or trigger input
signal.
Switch
Description (ON)
1
Adds an on-board pull-up resistor to the AUX(STB)_OPENC_OUT4+signal.
2
Adds an on-board pull-up resistor to the AUX(STB)_OPENC_OUT5+ signal.
3
Adds an on-board pull-up resistor to the AUX(USER)_OPENC_OUT6+ signal.
4
Adds an on-board pull-up resistor to the AUX(USER)_OPENC_OUT7+ signal.