Removing the Tray-1 unit / Tray-2 unit
1) Remove the finger-pinch prevention covers (front) and (rear).
2) Remove the 2 screws and then remove the tray stoppers (front) and (left).
4
Parts Replacement and Cleaning Procedure > Main Units > Removing the Tray-1 unit / Tray-2 unit
F-4-45
F-4-45
x2
F-4-46
F-4-46
4-24