Paper Switchback Position Adjustment - Canon Staple Finisher-D1 Service Manual

Hide thumbs Also See for Staple Finisher-D1:
Table of Contents

Advertisement

5
Adjustment > Basic Adjustment > Paper Switchback Position Adjustment

Paper Switchback Position Adjustment

Overview
Adjustment of the paper switchback position (stack delivery upper roller stop timing) when
stacking the buffered paper (A4/LTR/B5, 2 or 3 sheaves of paper) to the processing tray
unit.
Purpose of Adjustment
To correct the paper alignment at the sort and staple sort mode.
How to enter the adjustment mode
(1) Turn on the power with all SW3 keys set to OFF.
(2) Set the SW3 keys as shown below and press the SW1 continuously for two seconds.
ON
1 2 3 4
F-5-12
F-5-12
Adjustment Method
(1) The LED1 and LED2 indicate the current adjustment value.
(2) Pressing the SW1 reduces the value by 1 mm.
Pressing the SW2 increases the value by 1 mm.
(3) The LED1 and LED2 light for 500 ms.
(4) The LED1 and LED2 indicate the new adjustment value.
Repeat steps (2) to (4) until the desired adjustment value is displayed.
(5) Pressing the SW1 continuously for two seconds writes the new adjustment value to the
EEPROM.
Pressing the SW2 continuously for two seconds cancels the new adjustment value.
(Be sure to cancel the new adjustment value before writing it to the EEPROM.)
(6) The LED2 goes out and the LED1 blinks at intervals of 0.5 seconds.
(7) Set all SW3 keys set to OFF.
5
Adjustment > Basic Adjustment > Paper Switchback Position Adjustment
Adjustment Range
The stack delivery upper roller[1] stop timing can be made 0-50 mm earlier. (It hastens the
switchback position of the buffered paper.) [Default: 0 mm]
[1]
Display of Adjustment Value
- The numbers of times the LED1 and LED2 blink indicate the adjustment value assuming
that the LED1 stands for a tens digit and the LED2 stands for a units digit. Each LED blinks
at intervals of 300 ms.
(If the LED1 blinks 1 time and the LED2 blinks 5 times, the adjustment value is 15mm (= 10
x 1 + 1 x 5). )
- Each LED stays lit for two seconds to indicate 0 (zero).
Example: Display of the adjustment value "15 mm"
Turn*
LED1
LED2
*(Blinks 1
Tens
1
digit
time)
2
Units
*(Blinks 5
3
digit
times)
4
○= Stays unlit, ●= Stays lit, *= Blinking
*: It repeats from the turn 1 to 4 during the adjustment value indication.
5-6
F-5-13
F-5-13
Remarks
Blinking interval: 300 ms.
LED1/LED2 stays unlit. (1 second)
Blinking interval: 300 ms.
LED1/LED2 stays unlit. (1 second)
T-5-5
T-5-5
5-6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Booklet finisher-d1

Table of Contents