4
Parts Replacement and Cleaning Procedure > Consumable Parts Requiring Periodic Replacement and Cleaning Points > Removing the Paper Holding Rubber
Removing the Static Eliminator (Grate-shaped lower guide unit)
1) Lift the tray 1 unit until it will stop. Remove the screw and take out the static eliminator.
Removing the Paper Holding Rubber
1) Lift the tray 1 unit until it will stop. Remove the paper holding rubber after drawing out the paper holding
lever.
4
Parts Replacement and Cleaning Procedure > Consumable Parts Requiring Periodic Replacement and Cleaning Points > Removing the Paper Holding Rubber
F-4-113
F-4-114
4-48
4-48