5
Adjustment > Basic Adjustment > Paper Bump Amount Adjustment at the high-accuracy punch mode

Basic Adjustment

Paper Bump Amount Adjustment at the high-accuracy
punch mode
Overview
Adjustment of the amount of bump of the paper against the stopper at the high-accuracy
punch mode.
Purpose of Adjustment
To correct the skew of the punch hole position.
How to enter the adjustment mode
(1) Turn on the power with all SW3 keys set to OFF.
(2) Set the SW3 keys as shown below and press the SW1 continuously for two seconds.
ON
1 2 3 4
F-5-2
F-5-2
Adjustment Method
(1) The LED1 and LED2 indicate the current adjustment value.
(2) Pressing the SW1 reduces the value by 1 mm.
Pressing the SW2 increases the value by 1 mm.
(3) The LED1 and LED2 light for 0.5 second. (The adjustment result has been accepted.)
(4) The LED1 and LED2 indicate the new adjustment value.
Repeat steps (2) to (4) until the desired adjustment value is displayed.
(5) Pressing the SW1 continuously for two seconds writes the new adjusment value to the
EEPROM.
Pressing the SW2 continuously for two seconds cancels the new adjustment value.
(Be sure to cancel the new adjustment value before writing it to the EEPROM.)
(6) The LED2 goes out and the LED1 blinks at intervals of 0.5 seconds.
(7) Set all SW3 keys set to OFF.
5
Adjustment > Basic Adjustment > Paper Bump Amount Adjustment at the high-accuracy punch mode
Adjustment Range
The bump amount can be adjusted in the 2 mm to 4 mm range. [Default: 2 mm]
Stopper
Display of Adjustment Value
- The numbers of times the LED1 and LED2 blink indicate the adjustment value assuming
that the LED1 stands for a tens digit and the LED2 stands for a units digit. Each LED blinks
at intervals of 300 ms.
(If the LED1 blinks 0 time and the LED2 blinks 2 times, the adjustment value is 2 mm (= 10
x 0 + 1 x 2). )
- Each LED stays lit for two seconds to indicate 0 (zero).
Example: Display of the adjustment value "2 mm"
Turn*
LED1
LED2
●(Stays lit for
Tens
1
digit
2 seconds)
2
Units
*(Blinks 2 times)
3
4
digit
○= Stays unlit, ●= Stays lit, *= Blinking
*: It repeats from the turn 1 to 4 during the adjustment value indication.
5-3
F-5-3
F-5-3
Remarks
LED1 stays lit (2 seconds)
LED1/LED2 stays unlit. (1 second)
Blinking interval: 300 ms.
LED1/LED2 stays unlit. (1 second)
T-5-2
T-5-2