Adjustment > Basic Adjustment > Buffer Operation Enable/Disable Mode Setting

Buffer Operation Enable/Disable Mode Setting

Overview
Enabling/disabling buffer operation
Purpose of Adjustment
- When placing the importance to the productivity: Enabling buffer position
- When placing the importance to the performance: Disabling buffer position
How to enter the adjustment mode
(1) Turn on the power with all SW3 keys set to OFF.
(2) Set the SW3 keys as shown below and press the SW1 continuously for two seconds.
ON
1 2 3 4
F-5-15
F-5-15
Setting Method
(1) The LED1 and LED2 indicate the current setting value.
(2) To enable buffer operation, press the SW1.
To disable buffer operation, press the SW2.
(3) The LED1 and LED2 light for 500 ms.
(4) The LED1 and LED2 indicate the new setting value.
(5) Pressing the SW1 continuously for two seconds writes the new setting value to the
EEPROM.
Pressing the SW2 continuously for two seconds cancels the new setting value.
(Be sure to cancel the new setting value before writing it to the EEPROM.)
(6) The LED2 goes out and the LED1 blinks at intervals of 0.5 seconds.
(7) Set all SW3 keys set to OFF.
5
Adjustment > Basic Adjustment > Buffer Operation Enable/Disable Mode Setting
Setting Range
1 = Enable, 2 = Disable (Default:1 (Enable))
When buffer operation is enabled, 0 is written to the EEPROM. When buffer operation is
disabled, 1 is written to the EEPROM.
Display of Setting Value
- The numbers of times the LED1 and LED2 blink indicate the setting value assuming that
the LED1 stands for a tens digit and the LED2 stands for a units digit. Each LED blinks at
intervals of 300 ms.
(If the LED1 blinks 0 time and the LED2 blinks 1 time, the setting value is 1 (= 10 x 0 + 1 x
1)(Enable). )
- Each LED stays lit for two seconds to indicate 0 (zero).
Example: Display of the setting value "1" (Enable)
Turn*
LED1
LED2
● (Stays lit for
Tens
1
digit
2 seconds)
2
Units
*(Blinks 1
3
digit
times)
4
○= Stays unlit, ●= Stays lit, *= Blinking
*: It repeats from the turn 1 to 4 during the adjustment value indication.
5-8
Remarks
LED1 stays lit (2 seconds)
LED1/LED2 stays unlit. (1 second)
Blinking interval: 300 ms.
LED1/LED2 stays unlit. (1 second)
T-5-7
T-5-7
5-8