0480.4-RACK SENS INTERMIT CONT, SHORTED TO LOW SOURCE

(SERVICE TOOL FAULT CODE 168) (B.20.A.92 - G.30.B.53)
CX840
0480.4 - RACK SENS INTERMIT CONT, SHORTED TO LOW SOURCE (SERVICE TOOL FAULT CODE 168)
Context:
Engine Disabled - fuel pump shut off
Cause:
Pump control error (Internal fault within the fuel injection pump)
Possible failure modes:
1.
Faulty fuel injection pump assembly
Solution:
1.
Replace fuel injection pump
A.
NOTE: Prior to replacing the fuel injection pump inspect the connector to the pump and ensure the fit is good
and that there is no pin damage within the connector.
POWER PRODUCTION - FUEL AND INJECTION SYSTEM
2 4/7/2006
B.20.A / 257