22.
Securely attach the main hydrostatic pump to a tow
motor. Remove the mounting cap screws and lift the
pump from the combine. Store the pump in a suitable
location.
NOTE: The main hydrostatic pump weighs approximately
137 kg (303 lbs).
23.
Turn out the two cap screws (1) to detach the pipe
bracket (2) from the gearbox.
24.
Loosen the two hose clamps (1) remove and cap the
hydraulic lines from the gearbox.
Detach electrical connector (2).
POWER TRAIN - PROCESS DRIVE Primary process drive
2 4/7/2006
C.50.B / 19
22
10012190
23
10012193
24
10012194