New Holland CX720 Repair Manual page 2458

Hide thumbs Also See for CX720:
Table of Contents

Advertisement

Reservoir Capacity
Total System Capacity (Hydraulic and Hydrostatic)
Pressure Limiter
Relief Valve
Approximate system pressures expected during Testing:-
Neutral
Forward
Reverse
Forward Brakes on
Neutral
Forward
Reverse
Neutral
Forward
Reverse
Forward Brakes on
Neutral
Forward
Reverse
Reverse Brakes on
POWER TRAIN - TRANSMISSION Hydrostatic
Low Idle
36 Bar
522 PSI
28.3 Bar
410 PSI
29.5 Bar
428 PSI
26 Bar
377 PSI
Forward Servo
10 Bar
145 PSI
14 Bar
203 PSI
7 Bar
102 PSI
Low Idle
35 Bar
508 PSI
65 Bar
943 PSI
25 Bar
363 PSI
450 Bar
6525 PSI
Low Idle
35 Bar
508 PSI
20 Bar
290 PSI
65 Bar
943 PSI
450 Bar
6525 PSI
2 4/7/2006
C.20.F / 6
Approximately 36 Litres (38 qts.)
Approximately 70 Litres (74 qts.)
420 bar (6090 psi)
450 bar (6525 psi)
Charge Pressure
40.8 Bar
592 PSI
32.9 Bar
477 PSI
33.4 Bar
484 PSI
31 Bar
450 PSI
Servo Pressure
10 Bar
145 PSI
5 Bar
73 PSI
10.5 Bar
152 PSI
Forward Pressure
38 Bar
551 PSI
90 Bar
1305 PSI
30 Bar
435 PSI
456 Bar
6612 PSI
Reverse Pressure
35 Bar
508 PSI
20 Bar
290 PSI
80 Bar
1160 PSI
456 Bar
6612 PSI
High Idle
Reverse Servo
High Idle
High Idle

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cx740Cx760Cx780Cx820Cx840Cx860 ... Show all