New Holland CX720 Repair Manual page 2325

Hide thumbs Also See for CX720:
Table of Contents

Advertisement

B.
If there is no continuity to ground, continue with step 7.
7.
Disconnect connector X005 on the side of the cab. Use a multimeter to check for continuity between connector
X005 pin 20 and chassis ground.
A.
If there is no continuity to ground, a short to ground is located in the main frame (MF) harness between
connector X010 and connector X005 wire 839 white. Locate the short and repair.
B.
If there is continuity to ground, a short to ground is located in the cab main (CM) harness between con-
nector X005 and connector X015 wire 839 white. Locate the short and repair.
8.
Turn the key switch to the ON position. Use the InfoView monitor - "Diagnose info" screen to manually power the
grid heater circuit. Use the multimeter to check for 12 volts between connector X066 pin 7 and chassis ground.
A.
If 12 volts is not present continue with Step 9.
B.
If 12 volts is found continue with Step 14.
9.
Turn the key switch to the ON position. Use the InfoView monitor - "Diagnose info" screen to manually power the
grid heater circuit. Disconnect connector X004 . Use the multimeter to check for 12 volts between connector
X004 pin 20 and chassis ground.
A.
If 12 volts is not present, continue with step 10.
B.
If 12 volts is present, there is an open circuit in the cab main (CM) harness between connector X004 pin
20 and connector X066 pin 7 wire 814 white. Locate open and repair.
10.
Disconnect connector X010. Use a multimeter to check for continuity between connector X010 pin 7 & pin 20
(engine (EN) harness side).
A.
If there is no continuity, there is an open circuit in the engine (EN) harness between connector X010 pins
7 and 20 wire 814 white. Locate open and repair.
B.
If there is continuity, continue with step 11.
11.
Turn the key switch to the ON position. Use the InfoView monitor - "Diagnose info" screen to manually power the
grid heater circuit. Disconnect connector X010 . Use the multimeter to check for 12 volts between connector
X010 pin 20 and chassis ground.
A.
If 12 volts is not present, continue with step 12.
B.
If 12 volts is present, there is an open circuit in the main frame (MF) harness between connector X010
pin 7 and connector X004 pin 20 wire 814 white. Locate open and repair.
12.
Key switch to the ON position. Use the InfoView monitor - "Diagnose info" screen to manually power the grid
heater circuit. Disconnect connector X005 . Use the multimeter to check for 12 volts between connector X005
pin 20 and chassis ground.
A.
If 12 volts is not present, continue with step 13.
B.
If 12 volts is present, there is an open circuit in the main frame (MF) harness between connector X010
pin 20 and connector X005 pin 20 wire 839 white. Locate open and repair
13.
Key switch to the ON position. Use the InfoView monitor - "Diagnose info" screen to manually power the grid
heater circuit. Use the multimeter to check for 12 volts between connector X015 pin J1-12 and chassis ground.
A.
If 12 volts is present, the open is between connector X005 pin 20 and connector X015 pin J1-12 wire
839 white.
B.
If 12 volts is not present, replace the CCM2 controller.
14.
Erase the fault code and continue operation.
A.
Series 1206-1347
Wiring harness - Electrical schematic frame 03 (A.30.A.88-C.20.E.03)
POWER PRODUCTION - STARTING SYSTEM
2 4/7/2006
B.80.A / 17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cx740Cx760Cx780Cx820Cx840Cx860 ... Show all

Table of Contents