Resist Gov Deviation Qty, Shorted To Low Source - New Holland CX720 Repair Manual

Hide thumbs Also See for CX720:
Table of Contents

Advertisement

0477.4-RESIST GOV DEVIATION QTY, SHORTED TO LOW SOURCE

(SERVICE TOOL FAULT CODE 165) (B.20.A.92 - G.30.B.53)
CX840
0477.4 - RESIST GOV DEVIATION QTY, SHORTED TO LOW SOURCE (SERVICE TOOL FAULT CODE 165)
Context:
Engine Disabled - fuel pump shut off
Cause:
Pump control error (Internal fault within the fuel injection pump)
Possible failure modes:
1.
Faulty fuel injection pump assembly
Solution:
1.
Replace fuel injection pump
A.
NOTE: Prior to replacing the fuel injection pump inspect the connector to the pump and ensure the fit is good
and that there is no pin damage within the connector.
POWER PRODUCTION - FUEL AND INJECTION SYSTEM
2 4/7/2006
B.20.A / 248