Shut-Off Under Voltage, Shorted To High Source - New Holland CX720 Repair Manual

Hide thumbs Also See for CX720:
Table of Contents

Advertisement

0436.3-SHUT-OFF UNDER VOLTAGE, SHORTED TO HIGH SOURCE

(SERVICE TOOL FAULT CODE 164) (B.20.A.92 - G.30.B.54)
CX840
0436.3 - SHUT-OFF UNDER VOLTAGE, SHORTED TO HIGH SOURCE (SERVICE TOOL FAULT CODE 164)
Context:
Engine Disabled - fuel pump shut off
Cause:
+5 Volts monitoring undervoltage (Internal fault within the fuel injection pump)
Possible failure modes:
1.
Faulty fuel injection pump assembly
Solution:
1.
Replace fuel injection pump
A.
NOTE : Prior to replacing the fuel injection pump inspect the connector, X203, to the pump and ensure the
fit is good and that there is no pin damage within the connector.
POWER PRODUCTION - FUEL AND INJECTION SYSTEM
2 4/7/2006
B.20.A / 157