X200-X202 Drive-Cliq Interfaces; X210 Ep Terminal / Temperature Sensor - Siemens SINAMICS S120 Equipment Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

8.6.2.2

X200-X202 DRIVE-CLiQ interfaces

Table 8- 49
X200-X202 DRIVE-CLiQ interfaces
Pin
1
2
3
4
5
6
7
8
A
B
Connector type
DRIVE-CLiQ socket
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking covers (50 pieces) Article No.: 6SL3066-4CA00-0AA0
8.6.2.3

X210 EP terminal / temperature sensor

Table 8- 50
X210 EP terminal / temperature sensor input
Terminal
1
2
3
4
Type: Screw terminal 1 (Page 384)
Max. connectable cross-section 1.5 mm
Further information regarding the temperature sensor may be found in the SINAMICS S120 Commissioning Manual,
1)
Section "Temperature sensors for SINAMICS components."
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
Control Units, Control Unit Adapters and operating components
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
M (0 V)
Function
+ Temp
1)
- Temp
1)
EP +24 V (Enable Pulses)
EP M1 (enable pulses)
(AWG 16)
2
Technical data
Transmit data +
Transmit data -
Receive data +
-
-
Receive data -
-
-
Power supply
Electronics ground
Technical data
Temperature sensor KTY84-130 / Pt1000 / PTC / bimetallic
switch with NC contact
Supply voltage: 24 VDC (20.4 ... 28.8 V)
Electrical isolation: Yes
Input current: typ. 4 mA at 24 V DC
8.6 Control Unit Adapter CUA32
283

Advertisement

Table of Contents
loading

Table of Contents