Siemens SINAMICS S120 Equipment Manual page 121

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Table 5- 26
Technical data of the PM240-2, FSC (200 V) (2/2)
Line voltage 3 AC 200 ... 240 V ±10 %
Article No.
without integrated line filter
with integrated line filter
Output current
Rated current I
1)
n
Base load current I
H
for S6 duty (40 %) l
S6
Peak current l
max
Type rating
2)
based on I
/ based on I
n
H
Rated pulse frequency
Max. pulse frequency
Power loss
Cooling air requirement
Sound pressure level LpA (1 m)
24 V DC supply
for the Control Unit
Rated input current
3)
Resistance value of the external braking
resistor
Max. cable length
to braking resistor
Line connection L1, L2,
Motor connection U2, V2, W2,
DC-link connection, connection for
braking resistor
DCP/R1, DCN, R2
Max. motor cable length
4)
shielded/unshielded
Degree of protection
Weight
without / with line filter
Rated current I
covers the load cycle for Low Overload.
1)
n
Rated power of a typical standard induction motor at 230 V 3 AC
2)
The input current depends on the motor load and line impedance. The input currents apply for a load with the type rating
3)
(based on I
) for a line impedance corresponding to u
rated
To observe the limit values of EN 61800-3 Category C2, for Power Modules PM240-2 with integrated line filter 50 m
4)
(shielded) is the max. motor cable length. A cable length up to 150 m is possible for C2 if you use an unfiltered Power
Module with an external line filter for Category C2 and a motor reactor.
Power loss in the cabinet is almost 0 kW. The total power loss is dissipated through the heat sink.
5)
Power loss in the control cabinet: 0.01 kW. The remaining power loss is dissipated through the heat sink.
6)
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
Internal
6SL3210-
6SL3211-
1PC22-2UL0
1PC22-2UL0
1PC22-2AL0
1PC22-2AL0
A
22.0
22.0
A
17.5
17.5
A
24.2
24.2
A
35.0
35.0
kW
5.5 / 4.0
5.5 / 4.0
kHz
4
4
kHz
16
16
kW
0.20
0.20
l/s
18.5
18.5
dB
64.9
64.9
A
1.0
1.0
A
28.6
28.6
Ω
≥ 20
≥ 20
m
15
15
Terminal connector
Cable cross-section: 6 ... 16 mm
Tightening torque: 1.3 Nm (11.5 lbf in)
m
50 / 100
IP20
in the cabinet:
IP20
outside: IP54
kg
5.0 / 5.2
5.9 / 6.2
= 1 %.
k
5.2 Blocksize Power Modules (PM240-2)
Push-through
Internal
6SL3210-
1PC22-8UL0
1PC22-8AL0
28.0
22.0
30.8
44.0
7.5 / 5.5
4
16
0.26
5)
18.5
64.9
1.0
36.4
≥ 20
15
(AWG 10 ... 6)
2
IP20
5.0 / 5.2
Power Modules
Push-through
6SL3211-
1PC22-8UL0
1PC22-8AL0
28.0
22.0
30.8
44.0
7.5 / 5.5
4
16
0.26
6)
18.5
64.9
1.0
36.4
≥ 20
15
in the cabinet:
IP20
outside: IP54
5.9 / 6.2
119

Advertisement

Table of Contents
loading