Technical Data; Control Unit Adapter Cua32; Description - Siemens SINAMICS S120 Equipment Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

8.5.6

Technical data

Table 8- 47
Technical data CUA31
6SL3040-0PA00-0AA0 / 6SL3040-0PA00-0AA1
Ambient temperature in operation
Electronics power supply
Voltage
Current (without DRIVE-CLiQ)
Power loss
Maximum DRIVE-CLiQ cable length
CUA31 with article number 6SL3040-0PA00-0AA0
CUA31 from article number 6SL3040-0PA00-0AA1
Weight
8.6

Control Unit Adapter CUA32

8.6.1

Description

The Control Unit Adapter CUA32 is used to connect a Power Module blocksize to an existing
DC/AC group with a higher-level control module, e.g. a CU320-2. Since the closed-loop
control is realized externally, for operation, a SINAMICS, SIMOTION, or SINUMERIK closed-
loop control is always required for several axes.
The CUA32 offers additional encoder interface (HTL / TTL / SSI).
The Control Unit Adapter CUA32 has the following interfaces (ports):
Table 8- 48
Type
DRIVE-CLiQ interface
EP terminal/temperature sensor
Power Module Interface (PM-IF)
24 V electronics power supply
Encoder interface (HTL/TTL/SSI
Only SSI encoders without incremental tracks can be operated on the CUA32.
1
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
Control Units, Control Unit Adapters and operating components
Interface overview of the CUA32
)
(1)
Unit
Value
°C
0 ... 55
V
24 V DC (20.4 ... 28.8)
DC
A
0.1
DC
W
2.4
m
50
m
100
kg
0.31
Number
3
1
1
1
1
8.6 Control Unit Adapter CUA32
281

Advertisement

Table of Contents
loading

Table of Contents