Figure 5-42
Power Module, frame size GX
5.3.2.2

Terminal Block X9

Table 5- 44
Terminal block X9
Terminal
1
2
3
4
5
6
7
8
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
Signal name
P24V
M
Reserved, do not use
Reserved, do not use
Main contactor
Main contactor
EP +24 V (Enable Pulses)
EP M1 (Enable Pulses)
Technical data
Voltage: 24 V DC (20.4 ... 28.8 V)
Current consumption: max 1.4 A
-
-
240 V AC/ max. 8 A
30 V DC/ max. 1 A
Supply voltage: 24 V DC (20.8 V ... 28.8 V)
Current consumption: 10 mA
The pulse inhibit function is only available when Safety
Integrated Basic Functions are enabled.
Power Modules