Siemens SINAMICS S120 Equipment Manual page 129

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Table 5- 34
Technical data of the PM240-2, FSD (400 V)
Line voltage 3 AC 380 ... 480 V ±10 %
Article No.
without integrated line filter
with internal line filter
Output current
Rated current I
1)
n
Base load current I
H
for S6 duty (40 %) l
S6
Peak current l
max
Type rating
2)
based on I
/ based on I
n
H
Rated pulse frequency
Max. pulse frequency
Power loss
without filter with filter
Cooling air requirement
Sound pressure level LpA (1 m)
24 V DC supply
for the Control Unit
Rated input current
Resistance value of the external braking
resistor
Max. cable length
to braking resistor
Line connection L1, L2, L3,
Motor connection U2, V2, W2,
DC link connection DCP, DCN
Connection for braking resistor R1, R2
Max. motor cable length
4)
no EMC Category
shielded / unshielded
with filter and shielded: EMC Category
C2
Degree of protection
Weight
without / with line filter
Rated current I
covers the load cycle for Low Overload.
1)
n
Rated power of a typical standard induction motor at 400 V 3 AC
2)
The values depend on the ambient temperature and the utilization level.
3)
Please observe the additional restrictions for the 6SL321.-1PE27-5UL0 Power Module
4)
● Motor cable length 50 to 100 m: Set the pulse frequency to 2 kHz.
● Motor cable length> 100 m: Reduce the base load current for each 10 m by 1 %.
Power loss in the control cabinet: 0.10 kW. The remaining power loss is dissipated through the heat sink.
5)
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
6SL3210-
1PE23-8UL0
1PE23-8AL0
A
38
A
32
A
45
A
64
kW
18.5 / 15
kHz
4
kHz
16
kW
0.57 / 0.58
l/s
55
dB
45 ... 65
3)
A
1.0
A
36
Ω
≥ 25
m
15
Screw terminal; Torx M5
Cable cross-section: 10 ... 35 mm
Tightening torque: 2.5 ... 4.5 Nm (22 lbf in / 40 lbf in)
Screw terminal; Torx M4
Cable cross-section: 2.5 ... 16 mm
Tightening torque: 1.2 ... 1.5 Nm (15 lbf in)
m
200 / 300
m
150
IP20
kg
16 / 17.5
5.2 Blocksize Power Modules (PM240-2)
Internal
6SL3210-
6SL3210-
1PE24-5UL0
1PE26-0UL0
1PE24-5AL0
1PE26-0AL0
45
60
38
45
54
72
76
90
22 / 18.5
30 / 22
4
4
16
16
0.70 / 0.71
0.82 / 0.83
55
55
45 ... 65
45 ... 65
1.0
1.0
42
57
≥ 25
≥ 15
15
15
(AWG 20 ... 10 / AWG 8 ... 2)
2
(AWG 20 ... 6)
2
16 / 17.5
17 / 18.5
Power Modules
Push-through
6SL3210-
6SL3211-
1PE27-5UL0
1PE27-5UL0
1PE27-5AL0
1PE27-5AL0
75
75
60
60
90
90
120
120
37 / 30
37 / 30
4
4
16
16
1.09 / 1.10
1.09 / 1.10
55
55
45 ... 65
45 ... 65
1.0
1.0
70
70
≥ 15
≥ 15
15
15
In the control
cabinet: IP20
outside: IP54
17 / 18.5
20 / 21.5
127