8.6.3

Connection example

Figure 8-20
Connection example for CUA32
8.6.4

Meaning of the LEDs

Table 8- 54
Meaning of the LEDs on the Control Unit Adapter CUA32
LED
Color
RDY
Red
(READY)
Green
-
OUT > 5V
Orange
Cause and rectification of faults
Information about the cause and rectification of faults can be found in the SINAMICS S120
Commissioning Manual.
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
Control Units, Control Unit Adapters and operating components
Status
Description
continuous light
At least one fault is present in this component.
continuous light
The component is ready for operation and cyclic DRIVE-CLiQ
communication is taking place.
Off
Electronics power supply is missing or outside permissible tolerance
range.
Power supply: ≤5 V.
Electronics power supply for measuring system available.
Power supply: >5 V.
Remark
continuous light
You must ensure that the connected encoder can be operated with a
24 V power supply.
If an encoder that is designed for a 5 V power supply is operated with
a 24 V power supply, this can destroy the encoder electronics.
8.6 Control Unit Adapter CUA32