8.4.2.7

X120 digital inputs (fail-safe)/EP terminal/temperature sensor

Table 8- 29
X120 Failsafe Digital Inputs/temperature sensor input
Terminal
1
2
3
4
5
6
7
8
9
10
11
12
Type: Spring-loaded terminal 1 (Page 384)
Max. cross-section that can be connected: 1.5 mm
DI: Digital input; DO: Digital output; F-DI: Fail-safe digital input
1)
Control of Power Modules chassis format:+Temp/-Temp deactivated, temperature input via terminal X41 of the Power
2)
Modules
Pure hardware delay
3)
The maximum cable length that can be connected is 30 m.
Fail-safe digital inputs
An F-DI consists of a digital input and a second digital input to which the cathode of the
optocoupler is connected.
Temperature sensor input
NOTICE
Damage to motor due to incorrectly connected KTY temperature sensor
If a KTY temperature sensor is connected with incorrect polarity, it is not possible to detect
when the motor overheats. Overheating can cause damage to the motor.
• Connect a KTY temperature sensor with the correct polarity.
Further information regarding the temperature sensor may be found in the SINAMICS S120
Commissioning Manual, "Temperature sensors for SINAMICS components" section.
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
Control Units, Control Unit Adapters and operating components
Designation
1)
+ Temp
2)
- Temp
2)
DI 16
F-DI 0
DI17+ / EP +24 V3
(Enable Pulses)
DI17- / EP M3
(Enable Pulses)
DI 18
F-DI 1
DI 19+
DI 19-
DI 20
F-DI 2
DI 21+
DI 21-
M1
(AWG 16)
2
8.4 Control Unit CU310-2 DP (PROFIBUS)
Technical data
Temperature sensors: KTY84-130 / Pt1000 / PTC
Measuring current through temperature sensor
connection: 2 mA
Voltage: -3 ... +30 V DC
Electrical isolation: yes
M1: Reference potential for DI16, DI18 and DI20
DI17-/DI19-/DI21-: Reference potential for
DI17/DI19/DI21
Input characteristic acc. to IEC 61131-2, type 1
Input voltage (including ripple)
"1" signal: 15 ... 30 V
"0" signal: -3 ... +5 V
Input current
at 24 V DC: typ. 3.2 mA
for "1" signal: > 0.5 mA
Input delay (typ.)
2)
for "0" → "1": 50 μs
For "1" → "0": 150 μs