8.6.2.4

X220 HTL/TTL/SSI encoder interface

Table 8- 51
X220 HTL/TTL/SSI encoder interface
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Connector type
15-pin sub D connector
NOTICE
Damage to motor due to incorrectly connected KTY temperature sensor
If a KTY temperature sensor is connected with incorrect polarity, it is not possible to detect
when the motor overheats. Overheating can cause damage to the motor.
• Connect a KTY temperature sensor with the correct polarity.
Table 8- 52
Specification of measuring systems that can be connected
Parameter
High signal level
(TTL bipolar at X220)
Low signal level
(TTL bipolar at X220)
High signal level
(HTL unipolar)
Low signal level
(HTL unipolar)
High signal level
(HTL bipolar)
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
Control Units, Control Unit Adapters and operating components
Signal name
+Temp
SSI_CLK
SSI_XCLK
P encoder 5 V / 24 V
P encoder 5 V / 24 V
P sense
M encoder (M)
-Temp
M sense
RP
RN
BN
BP
AN_SSI_XDAT
AP_SSI_DAT
Designation
Threshold
U
-
Hdiff
U
-
Ldiff
U
High
H
Low
U
High
L
Low
U
-
Hdiff
8.6 Control Unit Adapter CUA32
Technical data
KTY, Pt1000, PTC input or bimetallic
switch with NC contact
SSI clock, positive
SSI clock, negative
Encoder power supply
Encoder power supply
Sense input encoder power supply
Ground, encoder power supply
Ground for KTY, Pt1000, PTC or
bimetallic switch with NC contact
Ground sense input
R track positive
R track negative
B track negative
B track positive
A track negative / SSI data negative
A track positive / SSI data positive
Min.
Type
Max.
2
-
5
-5
-
-2
17
-
V
10
-
V
0
-
7
0
-
2
3
-
V
Unit
V
V
V
CC
V
CC
V
V
V
CC
285