Connection example 2: HTL encoder, unipolar, with reference signal
Figure 9-11
Because the physical transmission media is more robust, the bipolar connection should
1)
always be used. The unipolar connection should only be used if the encoder type does not
output push-pull signals.
Figure 9-12
The photo above shows the wire jumpers for connecting unipolar HTL encoders with a
reference signal.
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
Supplementary system components and encoder system integration
Connection example 2: HTL encoder, unipolar, with reference signal
Photo of connection example 2: SMC30, 30 mm wide
9.1 Sensor Modules
1)