Connecting

3.5 DRIVE-CLiQ interfaces X100 to X103

3.5
DRIVE-CLiQ interfaces X100 to X103
You connect all the components of the SINAMICS S120 drive system including motors and
encoders using the DRIVE-CLiQ interface.
Properties of a DRIVE-CLiQ interface
Table 3- 9
Property
Connector type
Cable type, inside the control cabinet
Cable type, outside the control cabinet
Blanking plug for closing unused DRIVE-CLiQ
interfaces
Note
The maximum permissible cable length is 100 m.
Pin assignment of a DRIVE-CLiQ interface
Table 3- 10
View
56
DRIVE-CLiQ interfaces X100 to X103
Pin assignment of DRIVE-CLiQ interfaces X100 to X103
Pin Signal
Type of signal
name
1
TXP
Output
2
TXN
Output
3
RXP
Input
4
-
-
5
-
-
6
RXN
Input
7
-
-
8
-
-
A
+ (24 V)
Voltage Output Voltage supply for DRIVE-CLiQ,
B
M (0 V)
Voltage Output Ground for 24 V
Version
DRIVE-CLiQ connector (RJ45 socket)
DRIVE-CLiQ standard
MOTION CONNECT
Blanking plugs are included in the scope of deliv-
ery of the SIMATIC Drive Controller.
Additional blanking plugs are available as acces-
sories.
Meaning
Transmit data +
Transmit data -
Receive data +
Reserved; no connection
Reserved; no connection
Receive data -
Reserved; no connection
Reserved; no connection
≤ 450 mA
Equipment Manual, 11/2019, A5E46600370-AA