Technical Data - Siemens SINAMICS S120 Equipment Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

6.2.2.5

Technical data

Table 6- 14
What is the technical data of the braking resistors
Article number
P
power (unit rating)
DB
P
power (peak power)
15
Max. current
Cable entry
Line connection
Max. cross-section that can be connected
Degree of protection
Width x height x depth
Thermostatic switch (NC contact)
maximum contact load
connecting cable
Weight
1) Dimensions including the mounting handles: 810 x 1325 x 485
Duty cycle
Figure 6-9
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
Unit
kW
kW
A
mm
kg
Duty cycle for braking resistors
6SL3000–1BE31-3AA0
25
125
189
Via cable gland M50
Via stud M10
50 mm² (AWG 1)
IP20
740 x 605 x 485
240 VAC / 10 A
50
DC link components
6.2 Chassis
6SL3000–1BE32-5AA0
50
250
378
Via cable gland M50
Via stud M10
70 mm² (AWG 2/0)
IP20
740 x 1325 x 485
1)
240 VAC / 10 A
120
187

Advertisement