Figure 8-3
8.3.2.2

X22 serial interface (RS232)

Table 8- 3
X22 serial interface (RS232)
Connector type
Features
The maximum data rate is:
● 120 kBaud at a load capacity of 1.0 nF
● 20 kBaud at a load capacity of 2.5 nF
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
CU310-2 PN interface to the Power Module (PM-IF)
Pin
Signal name
1
Reserved, do not use
2
XRXD_RS232
3
XTXD_RS232
4
Reserved, do not use
5
M
6
Reserved, do not use
7
Reserved, do not use
8
Reserved, do not use
9
Reserved, do not use
9-pin SUB D connector