7.5
DRIVE-CLiQ
7.5.1
DRIVE-CLiQ interface
X100 - X103 pin assignment
PIN
1
2
3
4
5
6
7
8
A
B
Use
DRIVE-CLiQ interfaces are used to connect SINAMICS S120 components to the PPU.
It has the following properties:
● Components can be independently expanded
● Automatic detection of components by the PPU
● Standardized interfaces to all components
● Uniform diagnostics down to the components
● Complete service down to the components
Cable specification for X100 - X103
Feature
Connector type
Cable type
Article number
Max. cable length
Note
Interfaces X100 to X103
The interfaces X100 to X103 provide power supply voltage 24V/450mA to connect encoder/
measuring systems like SME.
PPU 1740
Equipment Manual, 01/2019, A5E47615272B AA
Signal name
Signal type
TXP
O
TXN
O
RXP
I
--
--
--
--
RXN
I
--
--
--
--
--
--
--
--
Version
RJ45 socket with 180° cable outlet
MOTION-CONNECT
70 m
Meaning
Transmit data +
Transmit data -
Receive data +
Reserved
Reserved
Receive data -
Reserved
Reserved
Reserved
Reserved
Interface description
7.5 DRIVE-CLiQ