Electrical Connection; Safety Note For The Drive-Cliq Interface; Connecting The Stator Winding - Siemens 1PL622 Operating Instructions Manual

Three-phase induction motor, ac compact drives
Table of Contents

Advertisement

Fixing by means of motor feet
If the motor needs to be aligned, position metal shims underneath the feet in order to prevent
machine deformation.
The number of shims should be kept as low as possible i.e. stack as few as possible.
Fixing bolts
To securely mount the motor and reliably transfer the drive torque, use motor fixing bolts
(M12) with the required strength class (8.8) in accordance with ISO 898-1.
NOTICE
All flange motors must have stable suspension and be supported by means of the end-
shield feet (foot-flange type of construction). When carrying out commissioning, make sure
that the vibration values permitted in accordance with DIN ISO 10816-3 are maintained.
Motors that are mounted, as a result of their type of construction, to the wall using the
motor feet, must be fixed in place using an adequately dimensioned positive form fit (e.g.
using studs or mounting rails).
[ID: 331.02]
3.3

Electrical connection

3.3.1

Safety note for the drive-CLIQ interface

CAUTION
Electrostatically sensitive devices
The drive-CLIQ interface contains components that are susceptible to electrostatic
charging. DTouching connections on the sensor module with electrostatic charged hands or
tools can cause malfunctions.
Comply with ESD protection measures (Page 10).
[ID 962.01]
3.3.2

Connecting the stator winding

Circuit diagram
Details with respect to wiring and connecting the motor winding are laid down in the circuit
diagram. The circuit diagram is attached to the lid of the terminal box.
A5E00264365A
Siemens AG Operating Instructions 2.02 1PL622
Transport, assembly, and connection
3.3 Electrical connection
29