General Test Setup - Keysight PD1000A Startup Manual

Power device measurement system for advanced modeling
Hide thumbs Also See for PD1000A:
Table of Contents

Advertisement

On State and Off State S-Parameter Characterization

General Test Setup

1 Connect two PD1000A Bias T networks to your PD1000A Test Fixture as
Figure 32 Connecting Two Bias Ts to the Test Fixture (TO-247 fixture shown,
2 Refer to Figure 33 below. From the B2902A Precision SMU, connect the dual
66
shown below:
cable not shown)
The Bias Ts and the Test Fixture must be supported on a table or
bench top.
banana plug cables to the two PD1000A Bias T networks as follows:
a Connect four (two red and two black) dual banana plug cables to the Bias
T that provides bias voltage to the gate of the Device Under Test (DUT).
b The other ends of the dual banana plug cables connect to the B2902A
front panel Force High, Force Low, Sense High, and Sense Low connectors.
c Connect four (two red and two black) dual banana plug cables to the Bias
T that provides bias to the drain/collector of the DUT.
d The other ends of the dual banana plug cables connect to the B2902A rear
panel Force High, Force Low, Sense High, and Sense Low connectors.
Keysight PD1000A Power Device Measurement System Startup Guide
Test Requirements

Advertisement

Table of Contents
loading