YASKAWA E-S Series Product Manual page 154

Ac, dc power supply input and contact commands
Table of Contents

Advertisement

 CLLV
Set the pressing detection levels during pressing operation.
Select the cells to edit and enter the values directly.
Unit
Setting Range
%*
0 to 100
*
Percentage (%) of rated torque.
 PSPD
Specify the target speeds for pressing.
Select the cells to edit and enter the values directly.
Unit
Setting Range
Reference units/s
1 to 99,999,999
 INPOS
Specify the positioning completed widths for positioning operation and the pressing travel dis-
tances for pressing operation.
1.
Double-click the cell to edit.
The Positioning Completed Width/Pressing Travel Distance Dialog Box will be displayed.
2.
Set the positioning completed width for positioning operation or the pressing travel dis-
tance for pressing operation.
Using the Setting of PnB2D
Using the Same Value as the Previous Step
Clear the selection of the PnB2D is used Check Box and select the Same as previous step
Check Box.
Entering Values Directly
Clear the selections of the PnB2D is used Check Box and Same as previous step Check Box
and enter the value directly.
Default Setting
0
Default Setting
2,000
7.3 Program Table Operation
7.3.6 SigmaWin+ Procedures
7
7-27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgpss servopackSgmsl servomotor